- Research
- Open access
- Published:
Retention of nickel, cobalt and chromium in skin at conditions mimicking intense hand hygiene practices using water, soap, and hand-disinfectant in vitro
Journal of Occupational Medicine and Toxicology volume 19, Article number: 44 (2024)
Abstract
Background
During the COVID-19 pandemic, increased hand hygiene practices using water, soap and hand disinfectants, became prevalent, particularly among frontline workers. This study investigates the impact of these practices on the skin’s ability to retain the allergenic metals nickel, cobalt, and chromium. The study constitutes three parts: (I) creating an impaired skin barrier, (II) exposing treated and untreated skin to nickel alone, and (III) in co-exposure with cobalt and chromium.
Methods
Using full-thickness skin from stillborn piglets, in vitro experiments were conducted to assess retention of metals in skin at conditions mimicking intense hand hygiene practices. Treatment of skin with varying concentrations of sodium lauryl sulphate (SLS), to impair its barrier integrity was assessed. This was followed by exposure of treated and untreated skin to the metals, that were dissolved in Milli-Q water, 0.5% SLS, and ethanol respectively.
Results
Results showed that pre-treatment with 5% SLS impaired the skin barrier with regards to the measure of trans epidermal water loss (TEWL). Metal amounts retained in the skin were generally higher in treated than untreated skin. The highest amounts of metal retained in skin were observed for exposure to nickel in ethanol. Co-exposure to nickel, cobalt, and chromium in 0.5% SLS resulted in the highest amounts of total metal retention.
Conclusions
The in vitro findings highlight the increased risk of metal retention in skin due to an impaired barrier. The SLS concentration used in the current study corresponds to those used in many hand hygiene products. Hence, occupational settings with frequent exposure to water, soap and disinfectants need to consider protective measures not only for the irritant exposures themselves but also simultaneous exposure to allergenic metals.
Introduction
During the Coronavirus pandemic 2019 (COVID-19), hygiene practices changed and more frequent exposure to water and hand disinfectants was observed [1]. Several studies related to increased hygiene measures during this period, have focused on healthcare workers and how such COVID-19 related measures increased skin- health issues [2,3,4,5]. Correspondingly, an increased self-reported exposure to water, soap and usage of hand disinfectant were demonstrated in frontline workers and IT personnel, i.e., occupations outside of the hospital setting that required presence at the workplace and one that could largely work from home [6]. Additionally, frontline workers also reported higher frequency of hand eczema than IT personnel [6], which is in line with the associations between increased hand washing and hand eczema observed for healthcare workers [2,3,4,5].
The most common cause of occupational skin disease has previously been reported to be occupational contact dermatitis [7, 8], which depending on aetiology, can be divided into irritant contact dermatitis and allergic contact dermatitis. While water, detergents, and cleansers are among the most important irritants, also having the ability to impair the skin barrier [9,10,11], the allergenic metals nickel, cobalt and chromium are common causes of occupational contact dermatitis [12]. Simultaneous or consecutive exposure to both irritant/barrier damaging chemicals and allergens is common, not least in wet work occupations [13], including health care workers [14]. In addition, such combined exposures will affect the possibility and degree of penetration and retention of allergens into the skin, although to an unknown extent.
The hypothesis of this study was that increased hand hygiene practices, amidst the COVID-19 pandemic, could lead to an impaired skin barrier, which in turn, might affect the skin barrier’s ability to retain allergenic metals. To test this hypothesis, in vitro experiments were performed in accordance with the OECD Test Guideline for skin absorption [15] to study retention of metals, in different solvents. The aim was to elucidate to what degree skin penetration occurred at exposure, under conditions mimicking intensive hand cleaning with water, soap, hand sanitizer.
Methods
In in vitro-experiments to study retention of allergenic metals in skin, conditions mimicking intense hand hygiene practices using water, soap and hand-disinfectant, were obtained by simultaneous exposure to nickel alone or in combination with cobalt and chromium, and the exposure solvents Milli-Q water, 0.5% sodium lauryl sulphate (SLS) and ethanol, respectively. In addition, skin with impaired barrier properties, to further resemble damage from intensive hand hygiene, was created via pre-treatment with SLS. In practical terms, the study was divided into three different experimental parts; I - in which conditions causing an impaired skin barrier were tested and evaluated, II - in which treated and untreated skin were exposed to nickel in Milli-Q water, 0.5% SLS and ethanol, and III - in which treated and untreated skin were co-exposed to nickel, cobalt and chromium in Milli-Q water, 0.5% SLS and ethanol, Fig. 1. (Flowchart of the chronological order of the study can be found in Supplementary Material Figure S1). All material used in experiments were acid washed (soaked for 24 h in 10% HNO3, rinsed three times with ultrapure water and dried in ambient laboratory air) or cleaned with ethanol, to avoid any possible metal contamination.
Skin for experiments
Full-thickness skin of stillborn piglets from commercial breeders was used in the present study. As the animals were not bred for research purposes, the use is exempt from the Swedish Agency for Agriculture’s requirements for ethical vetting of research involving animals. Although the OCED TG 428 does not specify the use of pig skin, the GD 156 [16] state the fact that pig skin is considered an appropriate alternative to human skin, which is also in line with the results from a review of in vitro penetration studies by Barbero et Frasch [17]. Pig skin is routinely used in skin permeation assays as it has been shown to have similar permeability characteristic to human skin [17,18,19,20]. Stillborn piglet skin has also been reported to have comparable permeability to human skin for organic compounds [21, 22]. No data is available regarding its metal permeability, but it has been used in other studies of metal retention, for nickel, cobalt, chromium and lead [23, 24].
At arrival to the laboratory, stillborn piglets were rinsed with lukewarm water, after which skin integrity was checked by measuring the transepidermal water loss (TEWL, Dermalab, Cortex Technology, Hadsund, Denmark).
To simulate experimental exposure conditions affected by intense hand hygiene practices, the skin of stillborn piglets was washed with water and soap for 5 min (DAX Mildtvål Oparfymerad, KiiltoClean, Hyllie Stationstorg 2, Malmö, Sweden) or repeatedly treated 25 times with hand disinfectant (DES 75 vol%, LIV by Clemondo, Helsingborg, Sweden) in situ. Based on the results from TEWL measurements following each step in the procedure, the approach was concluded to not efficiently impair the skin barrier and hence, were not used for the experiments (for more information on TEWL values and the procedure see Supplementary Material TableS1).
Full thickness skin (mean thickness 0.86 ± 0.22 mm) was collected from the back and flank of the stillborn piglets (< 24 h post-mortem) and the effect of excision on the skin was checked measuring TEWL at four different locations in each skin piece. Skin thickness was measured with a digital micrometre (model number 293-666-20 Mitutoyo, Kawasaki, Japan). An average TEWL ≥ 11 g⋅m− 2⋅h− 1 was used as a cut-off for inclusion [25, 26]. However, no skin pieces had to be discarded. The average TEWL for the skin was 7.25 ± 1.22 g⋅m− 2⋅h− 1. Next, the skin was wrapped in polyethene film and aluminium foil and stored at − 20ºC until later use within 3 months.
On the day of experiments, using a sterile scalpel (Kiato, Sylak AB, Askim, Sweden) 3 × 3 cm skin pieces were cut from each frozen skin and placed in a petri dish to thaw for 30 min at room temperature. Thereafter, the barrier integrity of each skin piece was controlled. The measured TEWL of all skin samples were < 11 g⋅m− 2⋅h− 1.
Treatment of skin with SLS (I)
Pre-treatment of skin to alter the barrier integrity can be performed by physical means [27], but for the purposes of this study, a pre-treatment with aqueous SLS was elaborated based on the OECD TG 439 for in vitro skin irritation [28].
After the thawing of skin, 500 µl PBS (PBS, pH = 7.4, Gibco Life Technologies, Thermo Fisher Scientific, Waltham, MA, USA) was put in the petri dish underneath the 3 × 3 cm skin piece to prevent dehydration. The skin surface was exposed to 200 µl of SLS-solutions (diluted from 20% SLS in H2O, Sigma-Aldrich, Schnelldorf, Germany) at different concentrations; 0.5, 1, 2, 5, and 10% in Milli-Q water (18.2 MΩ ⋅ cm− 1, Merck Millipore, Darmstadt, Germany) for 1 h, covered by the petri dish lid [29]. The concentrations were chosen based on available literature where 0.5-2% SLS concentrations has been used to irritate human skin [11, 30, 31]. OECD test guidelines for in vitro skin irritation using reconstructed human epidermis suggest the use of 5% aqueous SLS as positive control [28]. Due to the different skin models used in the available literature, and to ensure that we select the SLS concentration with the highest effect on the skin barrier, we decided to test also 10%, a concentration above those reported in the previous literature. The SLS was removed by rinsing with 4 ml (2 ml per side) of deionized water (dH2O, 16.8 MΩ ⋅ cm− 1). In total, four replicate samples were produced for each concentration tested with skin originating from four different piglets. The experiments for the two highest concentrations 5 and 10% respectively, were repeated and the results are thus based on 8 replicate samples. The TEWL values for each skin sample was recorded 20 min after removing the treatment.
Franz diffusion cell experiments (II, III)
A series of experiments were conducted to evaluate the ability of the skin barrier to retain metals given conditions without and with SLS pre-treatment, to alter the skin barrier, and the simultaneous exposure to Milli-Q water, 0.5% SLS and ethanol, to mimic intensive hand hygiene practices using water, soap and hand sanitizer, respectively. The OECD TG 428 for skin absorption [15] and GD 156 [16] constituted the starting point for experiments with a focus on the study of the skin barrier as boundary for exposure.
Six jacketed Franz cells (orifice diameter 11.28 mm, corresponding to an exposure area of 0.95 cm2, receptor volume 3 ml, Permegear, Bethlehem, PA, USA) were mounted on an adapted magnetic stirrer plate (HP 6 Variomag, H + P Labortechnik, Munick, Germany) and by means of circulating water from a thermostat water bath (AT 110, Heto, Alleod, Denmark) the diffusion cells were tempered at 32ºC. PBS was used as receptor fluid and was kept stirred using Teflon coated magnetic stirring bars. Skin pieces were mounted onto the Franz cells 15 min before the start of metal exposures.
This study comprises twenty-four different exposure scenarios each tested on both treated and untreated skin (Table 1), with a dose range of relevance for occupational settings and exposure time that mimic real-life work periods (short exposure and full day work shift) [32,33,34]. In the experimental part II, skin was exposed to nickel (1.36 µmol corresponding to a dose of 80 µg Ni/cm2) dissolved in Milli-Q water, 0.5% SLS and ethanol (≥ 96%, v/v, TechniSolv®, France) for 2 and 8 h. In part III, skin was similarly co-exposed to equimolar amounts of nickel, cobalt and chromium (4.09 µmol corresponding to a dose of 80 µg Ni + 80 µg Co + 71 µg Cr/cm2) in the three exposure solvents. The donor solutions were prepared using two metal reference materials: a standard nickel stock solution (10 000 µg Ni/ml in 2.5% HNO3, Spectrascan, Teknolab, Ski, Norway) and a special, equimolar high concentration reference material of nickel + cobalt + chromium (Ni + Co + Cr 200 mmol/l in 10% HNO3, Spectrascan, Teknolab, Ski, Norway).
Once the skin exposures to metal were initiated, the donor compartment and sampling port were occluded with parafilm (PARAFILM®, American National Can™). Blank (Milli-Q) exposures were carried out in parallel to enable control for any metal baseline quantities found in the skin (Supplementary Material Figure S2).
Metal quantification
Post exposure, the skin surface was rinsed with 2 ml dH2O per side (4 ml in total). Biopsy punches (Kai medical, 8 mm diameter) were taken from the exposed area and placed in polypropylene-plastic tubes (12 ml, Sarstedt, Nümbrecht, Germany) with 1 ml of 67% HNO3 for 48 h (until fully digested). Prior to metal analysis, 50 µl of digested skin was diluted with 4.95 ml of dH20 and spiked with 20 µl of indium (1.255 µg In/ml, diluted from stock solution of 999 ± 5 µg In/ml in 2% HNO3, Spectrascan, Teknolab, Ski, Norway).
Quantitative analyses of Ni, Co and Cr were performed using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS iCAP Q Thermo Fisher Scientific, Qtegra version 2.10). Concentrations of 58Ni, 60Ni, 59Co, and 52Cr, were analysed in kinetic energy discrimination (KED) measurement mode using helium gas to reduce any polyatomic interference and argon as nebulizer gas, cool gas, and auxiliary gas.
Matrix-matched standards for calibration with the concentrations of 0, 0.1, 1, 5, 10, 50, 100 and 500 µg/l Ni, Co, Cr and Pb in 2% HNO3 (67–69% HNO3, VWR, Normatom, Leuven, Belgium) were diluted from single metal reference materials (Ni: 1001 ± 4 µg/ml in 2% HNO3 (v/v); Co: 1000 ± 3 µg/ml in 3% HNO3 (v/v); Cr: 1002 ± 4 µg/ml in 2% HNO3 (v/v); Pb: 998 ± 4 µg/ml in 0.5% HNO3 (v/v), Spectrascan, Teknolab, Ski, Norway).
To ensure statistical certainty, each sample was analysed three to five times. The limit of detection (LOD) (based on 7 concentration points of the STD curve in the ICP-MS) was set at 0.079 µg/l for 58Ni, 0.082 µg/l 60Ni, 0.004 µg/l 59Co, and 0.19 µg/l 52Cr. All exposed samples analysed were above LOD. Nickel quantities found in samples was calculated as an average of 58Ni and 60Ni.
Statistical analysis
Any statistical relationship between the amount of metal retained in skin at exposures to nickel alone or in combination with cobalt and chromium in three exposure solvents for treated and untreated skin at two different time-points were evaluated using the Mann-Whitney U-test (GraphPad Prism version 9.5.0).
To determine which variable (TEWL, skin thickness, +/- SLS treatment, single nickel or Ni + Co + Cr co-exposure in Milli-Q water, 0.5% SLS or ethanol, and exposure time) affect metal retention in skin, linear regression with log-transformed amount of retained metal was performed using R (Version 4.4.1 (2024-06-14 ucrt)).
Results
Conditions causing an impaired skin barrier (I)
The median of TEWL values recorded after each step in the preparation of skin for experiments, and after treatment with five different aqueous SLS concentrations (0.5%, 1%, 2%, 5% and 10%) respectively, are compiled in Table 2. A ∆TEWL was calculated from the difference between the measured TEWL value after freezing (post thawing) and the TEWL value after SLS treatment. The results show that among the tested concentrations, 5% aqueous SLS alters the skin barrier the most.
Skin exposure to nickel in Milli-Q water, 0.5% SLS and ethanol (II)
Higher amounts of nickel were generally measured in treated skin compared to untreated (Fig. 2, top), and the difference was statistically significant for nickel exposure in Milli-Q water. The highest degree of nickel retention was observed for the exposure in ethanol (0.20 and 0.26 µmol for the 2- and 8-hour time-points in treated skin, and 0.16 and 0.22 µmol for the 2- and 8-hour time-points in untreated skin, respectively) followed by exposure in 0.5% SLS and Milli-Q water. The same tendency, however less pronounced, was observed for the 2- and 8-hours skin exposure to nickel in 0.5% SLS (0.07 and 0.12 µmol for the treated skin and 0.06 and 0.08 µmol for the untreated skin) and Milli-Q water (0.09 and 0.11 µmol for the treated and 0.03 and 0.04 µmol for the untreated skin, respectively).
Measured amounts of metal (µmol) in treated (grey bars) and untreated skin (white bars) following exposure to metals in Milli-Q water, 0.5% SLS and ethanol for 2 and 8 h, respectively. Results from single exposure to nickel is shown in the top row. The results for the combined exposure to equimolar amounts of nickel, cobalt and chromium are displayed per metal (middle section) and added (bottom). Data is presented as mean values of from six replicate experiments (n = 6, data points) with bars showing the standard deviation. Statistically significant relationships were indicated as (*) for p-values < 0.01 and (**) for p-values < 0.001
Co-exposure to nickel, cobalt and chromium in Milli-Q water, 0.5% SLS and ethanol (III)
The proportion of nickel, cobalt and chromium amounts measured in treated as well as untreated skin after 2- and 8 h of exposure respectively, consistently reflected the equimolar conditions of the co-exposure to nickel cobalt and chromium (Fig. 2, middle). Similar as to the single exposure to nickel, larger amounts of metal were measured in the treated skin compared to untreated. When the retained amounts of nickel, cobalt and chromium were added, the total amount of metal in skin were found to be at the same level as for nickel single exposure in the cases of exposure in Milli-Q water and ethanol (Fig. 2, bottom). For the co-exposure of nickel, cobalt and chromium in 0.5% SLS, the total amounts of metal in skin were instead approximately three times the amounts of that from nickel single exposure and in the same range as for single and co-exposure in ethanol. The difference between metal amounts retained in treated skin was statistically significant only after 8 h of exposure to metals in 0.5% SLS (0.29 and 0.17 µmol Ni + Co + Cr in treated vs. untreated skin) while in ethanol the significance was obtained for both 2- and 8 h of exposure (0.07 and 0.16 µmol Ni + Co + Cr after 2 h and 0.13 and 0.27 after 8 h exposure in treated and untreated skin respectively). For metal co-exposure in Milli-Q water, there were similar amounts of the individual metals measured in skin after 2 h (0.01–0.02 µmol), while the treatment of skin resulted in higher, although not statistically significantly higher, amounts of total metals in skin after 8 h (0.12 µmol Ni + Co + Cr in treated compared to 0.06 µmol Ni + Co + Cr in untreated skin). More information on the individual amounts of Ni, Co, and Cr retained after co-exposure can be found in Supplementary Material Table S2.
Linear regression with log-transformed retained metal amounts
Among the independent variables tested, SLS pre-treatment, the exposure solvent (Milli-Q water, 0.5% SLS and ethanol), the exposure time and the metal combination have shown to affect the retention of nickel in skin in a statistically significant manner (Supplementary Material Table S3). Moreover, nickel skin retention is affected negatively (coefficient − 0.997) when in the presence of cobalt and chromium, meaning that the presence of other metals in the co-exposure results in lower nickel retention in skin, although the total metal content (Ni + Co + Cr) was higher (see also Fig. 2, bottom row).
In the linear model skin thickness and TEWL (see also Supplementary Material Figure S3 and S4) did not have a statistically significant effect on the nickel skin retention. The model analysis thus indicates that TEWL is not a good predictor of metal in the skin.
Discussion
The present study demonstrates how the skin’s ability to resist exposure and retain allergenic metals is affected by exposure conditions mimicking intensive hand hygiene practices using water, soap and hand sanitizer and impaired barrier properties. First, we found that experimental treatment of piglet skin with 5% SLS efficiently alters the barrier integrity by means of TEWL. By adopting an established OECD method for skin absorption, we then conducted in vitro experiments that confirmed the SLS treatment consistently facilitated nickel skin penetration, and that exposure to single nickel in ethanol resulted in the highest amount of nickel in skin, compared to that from exposure in Milli-Q water or 0.5% SLS. Finally, co-exposure to nickel, cobalt and chromium in Milli-Q water, 0.5% SLS or ethanol respectively, showed that the amount of metal measured in the skin reflected the equimolar conditions upon exposure and that none of the metals penetrated or retained in the skin more readily than the other. Furthermore, following metal co-exposure in Milli-Q water and ethanol, the metal amount detected in skin added up to similar levels as observed for exposure to nickel only, while for the exposure in 0.5% SLS, the total amount of metal measured in skin doubled.
Impairing the barrier properties of skin using SLS is recommended by OECD TG 439 for in vitro skin irritation [28] and was previously used e.g., in vivo to cause irritation in a study of skin deposition and penetration of nickel [31]. In the present case, SLS treatment of skin was the preferred option since it was considered to additionally contribute to exposure conditions aimed to mimic the effect of hand hygiene practices. SLS concentrations in consumer products typically ranges from 0.01 to 50% in cosmetic products and 1–30% in cleaning products [30]. In a series of experiments, we investigated at which concentration the SLS treatment was most effective with respect to changed barrier properties and thus increased TEWL. We found that 5% SLS was more effective than treatment with 10% SLS, despite a relatively large variability among the 8 replicates from two different piglet individuals (Table 2). The TEWL measure reflects stratum corneum integrity, i.e., the main barrier for permeation resistance, and serves as a predictor of solvent permeation [35]. However, it does not seem to be a good predictor of metal retention in skin, as no correlation was observed between measured amounts of metal in skin and the degree of TEWL changes (Supplementary Material Figure S4). Alternative measures, in human skin, of natural moisturizing factor (NMF) and IL-1α are promising markers for other types of barrier properties such as permeation in deeper skin layers and inflammatory parameters [10], but more research is needed to determine their usefulness as a predictor for skin uptake of allergenic metals.
The results from exposure of untreated and treated skin, confirmed that the SLS pre-treatment enhances penetration of nickel and higher amounts of nickel were retained in skin compared to the untreated case. This is in line with previous findings on irritancy and skin damage caused by SLS as evaluated by several methods including the TEWL measure [9, 36, 37] and the ability of SLS to enhance permeation of other compounds [38,39,40]. Although the exact mechanism of SLS on skin barrier function has not been clarified, studies have pointed to delipidization [41, 42], morphological changes of corneocytes [43], or to damage to the deeper nucleated layers of the epidermis [44, 45]. These changes to the lipid lamellae organization may have contributed to the higher increase of nickel into the SLS treated skin.
Also, water causes skin irritancy and disruption similar to that of surfactants [11] but no study to our knowledge have investigated the permeation enhancing capacity of water. Since the results of nickel in untreated skin from exposure in Milli-Q water is the lowest that we observe in our experiments, it is anticipated that the SLS, both the pre-treatment and the exposure to 0.5% SLS have a larger influence on metal penetration and retention in skin than the other tested exposure solvents. The highest measured levels in the skin were observed for exposure to nickel in ethanol, which at the same time showed a large variation between the repeated experiments. This can be partially explained by inter-individual skin differences rather than the ethanol itself, indicated also by the TEWL values observed (Table 2, Supplementary Material Figure S4). In addition, ethanol interacts with stratum corneum lipids [46] and is known to be a skin permeation enhancer [47], which could contribute to the explanation of the high nickel levels measured in the skin after ethanol exposure.
When comparing our results with human nickel penetration studies, a major limitation is that human volunteer studies only investigate nickel penetration in stratum corneum, and varying number of layers of stratum corneum as the commonly used method tape-stripping is difficult to standardise. However, human volunteer data do indicate that nickel penetrates beyond the stratum corneum more efficiently in cases of either a filaggrin mutation or pre-treatment of skin with SLS [31, 48]. The fact that we find more nickel in skin after SLS treatment than in the reported human studies, is likely a result of analysing the entire skin, and not only the stratum corneum. When comparing our data to other in vitro studies, using human skin, nickel powder has been shown to penetrate damaged skin to a higher extent, together with also cobalt and chromium powders [49]. Furthermore, nickel has been shown to quickly penetrate beyond the stratum corneum in skin after exposure using various methodologies. The results from an in vitro study using nickel salts [50] have shown that less nickel is recovered from the stratum corneum surface as the exposure time increases. Furthermore, findings from tape-stripping [51] and imaging mass spectrometry [52], indicate that nickel can penetrate the deepest layers of the stratum corneum and enter the upper living epidermis.
The measured amounts of nickel, cobalt and chromium in the skin after combined exposure showed proportionality with the equimolar composition of the metals upon exposure and thus no possible preferential retention of the allergenic metals could be demonstrated. Results show that metal penetration occur in a time-dependent manner, which is in line with previous observations of simultaneous exposure to several metals [23]. The same study reported that the sum of metals in co-exposure (Ni, Co and Cr) resulted in higher metal amounts measured in skin compared to their single-metal-exposure counterparts, a tendency that was observed only for the metal co-exposure in 0.5% SLS in the current study. For exposures in Milli-Q water and ethanol, i.e., without surfactant present, the sum of metals from co-exposure is similar to the amount of nickel in the single metal exposure case. This finding indicates the possibility that the skin’s ability to retain metals has a saturation limit determined by the status of the skin barrier and the magnitude of the dose, in other words, infinite or finite conditions.
The present study focussed on the skin retention of nickel under different exposure conditions and skin status. A disadvantage of this study design is that, for various reasons including time and resources, metal concentrations in the receptor have not been quantified. With the information on percutaneously absorbed amounts, a better understanding of the skin’s barrier properties and ability to retain the metals that penetrated stratum corneum, could have been obtained. Having studied the single exposures to cobalt and chromium would as well have contributed to understanding potential co-exposure effects also for these metals. Another obvious limitation of the current study is the number of replicated experiments (n = 6) and the number and distribution of piglet individuals exposed to metals (n = 18), where a larger scale would of course be desirable in order to control for inter-individual variations.
This study is occupationally relevant as it demonstrates that a damaged skin barrier can absorb metals into the stratum corneum and deeper layers. This finding is particularly important for the many occupational groups working with both metals and wet work. It is known that nickel, cobalt and to some extent also chromium allergy is prevalent in, for example, car mechanics, electroplaters, health care workers, cement workers, hard-metal workers and electronic workers [53,54,55,56,57,58,59]. Common exposure factors in these occupations are direct contact with metals in skin on hands, coupled to extensive cleaning of hands with water, soap and sometimes even abrasive creams. Therefore, careful attention to prevention is warranted in these types of occupations with regards to metal exposure and hand hygiene practices. Recommendations of hand hygiene practices could be developed into specific guidelines taking into consideration each case where the skin needs protection. This has to be done on a case-by-case approach since the exposure scenarios may vary substantially.
Conclusion
In this study, we have demonstrated that an SLS treatment of skin alters the skin barrier properties with regards to TEWL. Furthermore, we have investigated differences in nickel retention between treated and untreated skin and how it is affected by exposure to other allergenic metals and continued skin-altering treatment mimicking intensive hand hygiene practices in the form of water, a surfactant and ethanol. In all investigated exposure cases, the treated skin is subject to higher level of metal retention. The exposure to nickel in ethanol and combined exposure to metals in 0.5% SLS, respectively, constitute the most severe scenarios, leading to the highest metal retention cases. These findings are important, as they show that hygiene practices could lead to an increased retention of metals in the skin. This highlights the need for suitable skin protection practices that do not disrupt the skin barrier, especially for those occupations with a high metal exposure or wet work exposure in combination with metals exposure. Furthermore, future research should be focused on elaborating these findings in occupationally exposed worker cohorts, to validate the results of the study in real-life settings.
Data availability
No datasets were generated or analysed during the current study.
References
Szczuka Z, Abraham C, Baban A, et al. The trajectory of COVID-19 pandemic and handwashing adherence: findings from 14 countries. BMC Public Health. 2021;21(1):1791.
Guertler A, Moellhoff N, Schenck TL, et al. Onset of occupational hand eczema among healthcare workers during the SARS-CoV-2 pandemic: comparing a single surgical site with a COVID-19 intensive care unit. Contact Dermat. 2020;83(2):108–14.
Hamnerius N, Pontén A, Bergendorff O, Bruze M, Björk J, Svedman C. Skin exposures, Hand Eczema and facial skin disease in Healthcare workers during the COVID-19 pandemic: a cross-sectional study. Acta dermato-venereologica. 2021;101(9):adv00543.
Techasatian L, Thaowandee W, Chaiyarit J, et al. Hand Hygiene habits and Prevalence of Hand Eczema during the COVID-19 pandemic. J Prim care Community Health. 2021;12:21501327211018013.
Vindenes HK, Bertelsen RJ, Lygre SHL, Morken T, Møllerløkken OJ, Irgens-Hansen K. Changes in Infection Prevention Practices and occurrence of skin symptoms among Healthcare Workers, cleaners and Day-Care workers in Norway during the COVID-19 pandemic. Acta dermato-venereologica. 2023;103:adv00840.
Vilela L, Lagrelius M, Berglind IA, Midander K, Schenk L, Julander A. Water, soap, and hand-disinfectant exposure during the COVID-19 pandemic and self-reported hand eczema in frontline workers: a cross-sectional study. Contact Dermat. 2024;91(1):22–9.
Jacobsen G, Rasmussen K, Bregnhøj A, Isaksson M, Diepgen TL, Carstensen O. Causes of irritant contact dermatitis after occupational skin exposure: a systematic review. Int Arch Occup Environ Health. 2022;95(1):35–65.
Keegel T, Moyle M, Dharmage S, Frowen K, Nixon R. The epidemiology of occupational contact dermatitis (1990–2007): a systematic review. Int J Dermatol. 2009;48(6):571–8.
Ananthapadmanabhan KP, Moore DJ, Subramanyan K, Misra M, Meyer F. Cleansing without compromise: the impact of cleansers on the skin barrier and the technology of mild cleansing. Dermatol Ther. 2004;17:16–25.
Symanzik C, Kezic S, Jakasa I, et al. Effects of skin washing frequency on the epidermal barrier function and inflammatory processes of the epidermis: an experimental study. Contact Dermat. 2022;87(3):241–6.
Mikulowska A. Reactive changes in the Langerhans’ cells of human skin caused by occlusion with water and sodium lauryl sulphate. Acta dermato-venereologica. 1990;70(6):468–73.
Rustemeyer T, Elsner P, John SM, Maibach HI, editors. Kanerva’s occupational dermatology, second edition. Springer. 2012.
Diepgen TL. Occupational skin diseases. J Der Deutschen Dermatologischen Gesellschaft = J German Soc Dermatology: JDDG. 2012;10(5):297–315.
Coppeta L, Zordo D, Papa ML, Pietroiusti F, Magrini A. Skin sensitization among night shift and daytime healthcare workers: a cross sectional study. Cent Eur J Public Health. 2021;29(3):191–4.
OECD. Test No. 428: Skin Absorption: In Vitro Method. Paris, Organisation for Economic Co-operation and Development. 2004.
OECD. Guidance Notes on Dermal Absorption. Series on Testing and Assessment. No 156. Second edition. Paris, Organisation for Economic Co-operation and Development. 2022.
Barbero A, Frasch H. Pig and guinea pig skin as surrogates for human in vitro penetration studies: a quantitative review. Toxicol vitro: Int J Published Association BIBRA. 2009;23(1):1–13.
Schmook FP, Meingassner JG, Billich A. Comparison of human skin or epidermis models with human and animal skin in in-vitro percutaneous absorption. Int J Pharm. 2001;215(1–2):51–6.
Gerstel D, Jacques-Jamin C, Schepky A, et al. Comparison of protocols for measuring cosmetic ingredient distribution in human and pig skin. Toxicol vitro: Int J Published Association BIBRA. 2016;34:153–60.
Ranamukhaarachchi SA, Lehnert S, Ranamukhaarachchi SL, et al. A micromechanical comparison of human and porcine skin before and after preservation by freezing for medical device development. Sci Rep. 2016;6:32074.
Cilurzo F, Minghetti P, Sinico C. Newborn pig skin as model membrane in in vitro drug permeation studies: a technical note. AAPS PharmSciTech. 2007;8(4):E94.
Schenk L, Rauma M, Fransson MN, Johanson G. Percutaneous absorption of thirty-eight organic solvents in vitro using pig skin. PLoS ONE. 2018;13(10):e0205458.
Midander K, Schenk L, Julander A. A novel approach to monitor skin permeation of metals in vitro. Regul Toxicol Pharmacology: RTP. 2020;115:104693.
Julander A, Midander K, Garcia-Garcia S, Vihlborg P, Graff P. A case study of brass Foundry Workers’ estimated lead (pb) body burden from different exposure routes. Annals work Exposures Health. 2020;64(9):970–81.
Pinnagoda J, Tupker RA, Agner T, Serup J. Guidelines for transepidermal water loss (TEWL) measurement. A report from the Standardization Group of the European Society of Contact Dermatitis. Contact Dermat. 1990;22(3):164–78.
Zhang Q, Murawsky M, LaCount T, Kasting GB, Li SK. Transepidermal water loss and skin conductance as barrier integrity tests. Toxicol vitro: Int J Published Association BIBRA. 2018;51:129–35.
Filon FL, Boeniger M, Maina G, Adami G, Spinelli P, Damian A. Skin absorption of Inorganic lead (PbO) and the Effect of skin cleansers. J Occup Environ Med. 2006;48(7):692–9.
OECD. Test No. 439: In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method. Paris, Organisation for Economic Co-operation and Development. 2021.
York M, Griffiths HA, Whittle E, Basketter DA. Evaluation of a human patch test for the identification and classification of skin irritation potential. Contact Dermat. 1996;34(3):204–12.
Bondi CA, Marks JL, Wroblewski LB, Raatikainen HS, Lenox SR, Gebhardt KE. Human and Environmental Toxicity of Sodium Lauryl Sulfate (SLS): evidence for Safe Use in Household Cleaning products. Environ Health Insights. 2015;9:27–32.
Ahlström MG, Midander K, Menné T, et al. Nickel deposition and penetration into the stratum corneum after short metallic nickel contact: an experimental study. Contact Dermat. 2019;80(2):86–93.
Kettelarij J, Midander K, Lidén C, Bottai M, Julander A. Neglected exposure route: cobalt on skin and its associations with urinary cobalt levels. Occup Environ Med. 2018;75(11):837–42.
Klasson M, Lindberg M, Bryngelsson IL, et al. Biological monitoring of dermal and air exposure to cobalt at a Swedish hard metal production plant: does dermal exposure contribute to uptake? Contact Dermat. 2017;77(4):201–7.
Lidén C, Skare L, Nise G, Vahter M. Deposition of nickel, chromium, and cobalt on the skin in some occupations - assessment by acid wipe sampling. Contact Dermat. 2008;58(6):347–54.
Kezic S, Nielsen JB. Absorption of chemicals through compromised skin. Int Arch Occup Environ Health. 2009;82(6):677–88.
Laudańska H, Reduta T, Szmitkowska D. Evaluation of skin barrier function in allergic contact dermatitis and atopic dermatitis using method of the continuous TEWL measurement. Roczniki Akademii Medycznej w Bialymstoku (1995). 2003;48:123–7.
Welzel J, Metker C, Wolff HH, Wilhelm KP. SLS-irritated human skin shows no correlation between degree of proliferation and TEWL increase. Arch Dermatol Res. 1998;290(11):615–20.
Nielsen JB. Percutaneous penetration through slightly damaged skin. Arch Dermatol Res. 2005;296(2):560–7.
Benfeldt E, Serup J. Effect of barrier perturbation on cutaneous penetration of salicylic acid in hairless rats: in vivo pharmacokinetics using microdialysis and non-invasive quantification of barrier function. Arch Dermatol Res. 1999;291(9):517–26.
Pavlačková J, Egner P, Polašková J, et al. Transdermal absorption of active substances from cosmetic vehicles. J Cosmet Dermatol. 2019;18(5):1410–5.
Froebe CL, Simion FA, Rhein LD, Cagan RH, Kligman A. Stratum corneum lipid removal by surfactants: relation to in vivo irritation. Dermatologica. 1990;181(4):277–83.
Imokawa G, Akasaki S, Minematsu Y, Kawai M. Importance of intercellular lipids in water-retention properties of the stratum corneum: induction and recovery study of surfactant dry skin. Arch Dermatol Res. 1989;281(1):45–5.
Shukuwa T, Kligman AM, Stoudemayer TJ. A new model for assessing the damaging effects of soaps and surfactants on human stratum corneum. Acta dermato-venereologica. 1997;77(1):29–34.
Fartasch M, Schnetz E, Diepgen TL. Characterization of detergent-induced barrier alterations -- effect of barrier cream on irritation. J Invest Dermatology Symp Proc. 1998;3(2):121–7.
Yang L, Mao-Qiang M, Taljebini M, Elias PM, Feingold KR. Topical stratum corneum lipids accelerate barrier repair after tape stripping, solvent treatment and some but not all types of detergent treatment. Br J Dermatol. 1995;133(5):679–85.
Gupta R, Badhe Y, Rai B, Mitragotri S. Molecular mechanism of the skin permeation enhancing effect of ethanol: a molecular dynamics study. RSC Adv. 2020;10(21):12234–48.
Ghanem AH, Mahmoud H, Higuchi WI, Liu P, Good WR. The effects of ethanol on the transport of lipophilic and polar permeants across hairless mouse skin: Methods/validation of a novel approach. Int J Pharm. 1992;78(1–3):137–56.
Julander A, Liljedahl ER, Korres de Paula H, et al. Nickel penetration into stratum corneum in FLG null carriers-A human experimental study. Contact Dermat. 2022;87(2):154–61.
Larese F, Gianpietro A, Venier M, Maina G, Renzi N. In vitro percutaneous absorption of metal compounds. Toxicol Lett. 2007;170(1):49–56.
Tanojo H, Hostýnek JJ, Mountford HS, Maibach HI. In vitro permeation of nickel salts through human stratum corneum. Acta dermato-venereologica Suppl. 2001;212:19–23.
Hostýnek JJ, Dreher F, Pelosi A, Anigbogu A, Maibach HI. Human stratum corneum penetration by nickel. In vivo study of depth distribution after occlusive application of the metal as powder. Acta dermato-venereologica Suppl. 2001;81(212):5–10.
Malmberg P, Guttenberg T, Ericson MB, Hagvall L. Imaging mass spectrometry for novel insights into contact allergy - a proof-of-concept study on nickel. Contact Dermat. 2018;78(2):109–16.
Meding B, Barregård L, Marcus K. Hand Eczema in car mechanics. Contact Dermat. 1994;30(3):129–34.
Kanerva L, Kiilunen M, Jolanki R, Estlander T, Aitio A. Hand Dermatitis and allergic patch test reactions caused by nickel in electroplaters. Contact Dermat. 1997;36(3):137–40.
Coppeta L, De Zordo LM, Papa F, Pietroiusti A, Magrini A. Skin sensitization among night shift and daytime healthcare workers: a cross sectional study. Cent Eur J Public Health. 2021;29(3):191–4.
Wang BJ, Wu JD, Sheu SC, et al. Occupational hand dermatitis among cement workers in Taiwan. J Formos Med Association = Taiwan Yi Zhi. 2011;110(12):775–9.
Fischer T, Rystedt I. Cobalt allergy in hard metal workers. Contact Dermat. 1983;9(2):115–21.
Bock M, Schmidt A, Bruckner T, Diepgen TL. Occupational skin disease in the construction industry. Br J Dermatol. 2003;149(6):1165–71.
Shiao JS, Sheu HM, Chen CJ, Tsai PJ, Guo YL. Prevalence and risk factors of occupational hand dermatoses in electronics workers. Toxicol Ind Health. 2004;20(1–5):1–7.
Acknowledgements
We would like to acknowledge MD. Ina Anveden Berglind and MD. Maria Lagrelius for their help translating high intensity hand washing practices from those observed in clinical setting to in vitro experiment.
Funding
Open access funding provided by Karolinska Institute. The study was financed by research grants from the AFA Insurance (Dnr 200230), PI Anneli Julander.
Author information
Authors and Affiliations
Contributions
Vilela, L. and Midander, K. wrote the main manuscript text and the supplementary material. Vilela, L. prepared Figs. 1 and 2; Table 1 and Figures S1-S4 and Tables S1-S3 and oversaw the software used in the manuscript. All authors took part in the investigation, formal analysis, visualization and reviewing and editing of the manuscript. Schenk, L., Julander, A. and Midander, K. took part on the conceptualization, validation, methodology, data curation and supervision. Julander, A. was in charge of the funding acquisition and is also the project leader.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
All authors have approved the submission of the manuscript and consent for its publication in the Journal of Occupational Medicine and Toxicology.
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Vilela, L., Schenk, L., Julander, A. et al. Retention of nickel, cobalt and chromium in skin at conditions mimicking intense hand hygiene practices using water, soap, and hand-disinfectant in vitro. J Occup Med Toxicol 19, 44 (2024). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12995-024-00442-5
Received:
Accepted:
Published:
DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12995-024-00442-5